Plastixal aluminum facade MC WALL

MC Wall

  • a system used to design modern curtain walls; the system is a basis for facade structures: MC Passive, MC Passive+, MC Glass and MC Fire, MC Glass Fire (a solution for fire protection); the MC Wall system offers many possibilities of creating the installation; the system offers structures to be opened on the facade: parallel windows (MC PW) and roof windows (MC RW)
  • mullion-transom visual width: 55 mm
  • the curtain wall in the MC Wall system consists of mullions and transoms fastened by stainless steel bolts; there are 2 x ø 6 stainless steel fasteners per joint; the fasteners ensure very high load capacity of the mullion-transom connection, both in the wind pressure plane and the infill load plane; the solution does not prevent using traditional transom brackets or fastening transoms only with screws attached from the face side
  • a wide range of mullions and transoms suitable for static requirements
  • the insulators can be built accordingly to the infill thickness
  • application of vapour-proof and breather membranes on the perimeter of the facade is easier, in accordance with new guidelines for installation of aluminium structures
  • a wide range of decorative cover caps makes it possible to obtain varied visual effects on the curtain wall
  • the option of bending profiles (detailed specification of profiles and detailed technical parameters of profile bending process are available in the customer area of the website www.aliplast.pl)
  • a wide range of colours available – RAL palette (Qualicoat 1518), structural colours, Aliplast Wood Colour Effect (Qualideco PL-0001), anodized (Qualanod 1808), bi-colour

TECHNICAL SPECIFICATION

systemmaterialdepth mulliondepth transomglazing rangemullions rigiditytransom rigidity
MC WALL
aluminium10-326 mm10-294 mm4-59 mmfrom 10,2 – 4092 cm4*from 7,0 to 1831,1*

PERFORMANCE

systemthermal insulation Uf*air permeabilitywindload resistancewatertightness
MC WALL
Uf from 0,84 W/m2KClass AE1500; EN 12152 2600Pa – 3900Pa; EN 13116
Class RE1950; EN 12154
*there is a possibility to use additional reinforcements
**thermal insulation is dependent on a combination of profiles and thickness of the filling

Download full MC Wall – Fixed Window Wall Combination Certificate
SPECIFICATION:
ASTM E283, ASTM E547, ASTM E331, ASTM E330

Selected projects with the MC WALL façade

Change device with QR code

If you want to open this website on another device, you do not need to enter the address. Just scan the QR code and explore our products wherever it is convenient for you.